Materials

Board and Batten Siding in Portland: Materials, Rules & Cost

Board and batten siding on Portland houses: the cedar, fiber cement, LP and vinyl versions, what each needs behind it, local design rules and costs.

Board and batten siding is vertical siding: wide boards or panels run up the wall, and narrow battens cover the joints between them. On Portland-area houses it is built in four ways, in cedar boards, fiber cement panels, LP SmartSide engineered wood and vinyl, and every version needs the same things behind it: something solid to nail into, a drained water-resistive barrier, and careful detailing where the boards end, at the bottom of the wall and at any joint across it.

This guide compares the four from the makers’ current installation instructions and Oregon’s residential code. Oregon’s 2026 residential code has been in force since October 1, 2026, and until March 31, 2027 building departments must also accept work designed to the 2023 edition (OAR 918-480-0005); the sections cited here are the 2023 edition’s. Every source was read on October 7, 2026.

What board and batten siding is

In the Western Red Cedar Lumber Association’s description, wide boards are set with a gap between them and a narrow batten closes each gap. There are no set widths: 1x10 boards with 1x3 battens are a common pairing, and the pattern can be reversed, boards over battens, for a deeper channel (WRCLA). Two differences from lap siding decide how it is installed:

  • The boards run alongside the studs. A vertical board may never cross one, so the wall needs horizontal blocking, furring or solid sheathing for the nails.
  • Every board ends at the bottom of the wall. Its end grain sits along the whole bottom edge, and again at any joint across a tall wall, which are the places water collects.

Much of it is now built from panels with battens over the seams: James Hardie pairs its panel siding with trim battens (James Hardie), and LP offers panels, a 16-inch vertical siding or lap run vertically (LP).

Four ways it is built on Portland houses

Cedar boards and battens Fiber cement panel and battens LP SmartSide Vertical vinyl
What goes on the wall Separate boards, with battens nailed over the gaps 4-by-8, 4-by-9 or 4-by-10 sheets, with battens over the seams Panels with trim battens, 16-inch-wide vertical siding, or lap boards run vertically Vinyl panels in a vertical board-and-batten profile
What it nails into Horizontal blocking or furring Studs 24 inches apart or closer, or 7/16-inch OSB Studs 16 or 24 inches apart, by panel series, or 7/16-inch structural sheathing (sheathing only, for vertical lap) Horizontal furring 12 inches apart, or solid nailable sheathing, where the wall needs it
Joints across the wall Flashing at every change of material or direction Z-flashing with an open 1/4-inch gap; no panel may span a floor A flashed or lapped seam, with no batten across it Inverted J-channel, head flashing and a 3/8-inch gap
Bottom of the wall 6 inches above the ground, end grain sealed 6 inches above the ground, 1 inch above roofing 6 inches above the ground, 1 inch above roofing A J-channel or vertical base with weep holes

Cedar boards and battens

The cedar association’s nailing guidance lets each piece move with the weather. Boards up to 6 inches wide take one nail per bearing, through the center; wider boards take two, 2-1/2 to 3 inches apart; and each batten takes one nail driven through the gap between the boards, so it never pins two boards together. Battens over 6-inch boards spaced half an inch apart overlap each board by at least half an inch.

Its pre-installation notes ask for hot-dipped galvanized, aluminum or stainless nails, stainless first, since copper and plain steel stain cedar; blocking no more than 36 inches apart over wood sheathing for face-nailed boards, 32 for blind-nailed, 24 with no sheathing; and the bottom edge 6 inches above the ground, end grain coated in water repellent, 2 inches above any roof or deck.

The association’s minimum nail penetration is 1-1/4 inches. Oregon’s code asks for 1-1/2 inches into studs, studs and wood sheathing together, or blocking (2023 ORSC R703.3.4), and the code governs. Grades and finish cycles are on the cedar siding page.

Fiber cement panel and battens

James Hardie’s panel siding, long sold as HardiePanel, is 5/16 inch thick, in 4-by-8 to 4-by-10 sheets, with smooth, Cedarmill, stucco and Sierra 8 textures. Its HZ10 panel instructions (effective December 2019; the copy on file with Florida’s product approval system) put panels over studs no more than 24 inches apart or onto 7/16-inch OSB, joined over a stud and nailed 3/8 inch from edges and 2 inches from corners. Vertical joints are butted, caulked (not on factory-finished ColorPlus panels), H-molded or battened. Every horizontal joint gets Z-flashing with a 1/4-inch gap above it that is never caulked, and no panel may bridge a floor. Primed panels are painted within 180 days, and Hardie recommends an air gap behind the panels as best practice.

Battens cover a joint by at least 3/4 inch on each side, in Hardie’s best-practices guide, and its trim instructions (September 2025) give a batten a 22.5 to 45 degree weather cut above a horizontal joint, or stop it at a band board, with 2-inch finish nails at most 16 inches apart into framing or sheathing. These are Hardie’s HZ10 instructions; hardiezone.com gives the zone for an address. The fiber cement siding page covers the material’s trade-offs.

LP SmartSide panel, vertical siding and lap

LP’s panel instructions (form LPZB0512, April 26, 2024) put its 38 and 76 Series panels on studs no more than 16 inches apart and its 190 Series on studs up to 24 inches, or any of them on 7/16-inch structural sheathing, nailed every 6 inches along the edges and 12 in the field with heads snug, not sunk. Horizontal seams are flashed, with a 3/8-inch gap over a sloped flashing, or lapped an inch, and LP’s drawings say not to run a batten or trim across one. LP does not recommend its panels over furring strips in the United States and will not cover buckling if they are used; an entangled drainage mat is allowed. Every cut is sealed, and the siding is painted within 180 days, never stained.

Lap boards run vertically follow LP’s lap instructions (LPZB0515, December 8, 2023): nailed to 7/16-inch structural sheathing, edges 3/16 inch apart, and, because LP expects the wall plates to shrink, no batten or vertical lap past one floor-to-ceiling height except when an existing house is re-sided. The LP SmartSide guide covers the product and its warranty.

Vertical vinyl

The Vinyl Siding Institute’s installation manual covers vertical vinyl separately. Horizontal furring strips 12 inches apart, or solid nailable sheathing, go on where the wall needs leveling or more material for the nails. Panels stand in a J-channel or vertical base drilled with 3/16-inch weep holes no more than 24 inches apart, hang from a nail at the top of their highest slot with room to move 1/4 inch up and 3/8 inch down, and take the rest of their nails centered in the slots no more than 12 inches apart. A wall too tall for one length is split with an inverted J-channel, head flashing and a second J-channel, leaving a 3/8-inch gap. Oregon’s code sets the same 12-inch spacing unless the maker allows more (2023 ORSC R703.11.1). How vinyl handles heat, and why panels nailed tight ripple, is on the vinyl siding page.

What has to be behind vertical siding

Oregon’s residential code sets four minimums for the wall behind it:

  1. A nailing base. Nails in wood siding reach 1-1/2 inches into studs, studs and wood sheathing together, or blocking (R703.3.4), and the code’s optional schedule for nailing into sheathing alone “does not apply to vertical siding” (Table R703.3.3). That means horizontal blocking, horizontal furring, or panels fastened as their makers allow.
  2. A water-resistive barrier, continuous behind the siding (R703.2).
  3. A drainage space of at least 1/8 inch, formed with furring, a drainage mat or a drainage board, unless an exception applies; one accepts a barrier made to drain that meets a 75 percent drainage-efficiency test, ASTM E2273 (R703.1.1).
  4. Flashing at windows and doors, above projecting trim such as a band board, and a kick-out wherever a roof edge ends against a wall (R703.4).

Items 1 and 3 pull against each other on a vertical wall: furring run horizontally for the nails also runs straight across the drainage space. The ways around it are a drainage mat or board, a barrier made to drain, or two layers of furring, vertical first and horizontal on top, a lattice the Department of Energy’s Building America Solution Center illustrates behind wood siding. LP advises against furring under its panels while Hardie recommends an air gap behind its own, so the quote should name the method.

Why the bottom edges and floor-line joints fail first

Portland’s rain falls mostly in the cool months: NOAA’s 1991-2020 normals give the airport about 37 inches a year, with more than 5 inches in each of November, December and January (NOAA). On a vertical wall that water runs down each board to an edge, and the edge is end grain. The USDA Forest Products Laboratory’s Wood Handbook (FPL-GTR-282, chapter 16) says liquid water enters wood 10 to 100 times faster through end grain than through the other faces, that paint only slows it, and that the edges of plywood and OSB contain end grain too. Its advice: seal end grain, leave space below each board so the bottom edge dries after rain, keep 3/8 to 1/2 inch between siding and a flashing that drains below it and 2 inches above a roof, and never use sealant in place of flashing.

The makers put the same physics into their rules. The cedar association, Hardie and LP all ask for 6 inches between the bottom of the siding and the ground. Joints across the wall stay open over their flashing: 1/4 inch and never caulked for Hardie, 3/8 inch for LP, 1/4 inch with no caulk where flashing meets trim for cedar. Cut edges are sealed or primed. And because Hardie’s panels may not bridge a floor, and on new work LP’s battens may not run past one storey, a two-storey wall in either gets a flashed joint at the floor line. On an existing board-and-batten wall, look there first: the bottom inches of each board, the floor-line joint, the lower ends of the battens, and any gap caulked shut that should be open.

Local rules that name board and batten

A few Portland-area design codes deal with board and batten by name, and they do not treat it alike.

  • Sherwood’s Old Town. In the Smockville part of the Old Town Overlay, the residential design standards list “true board and batten vertical wood siding, painted” among the permitted sidings, and they prohibit T-111 and similar 4-by-8 sheet materials or plywood (Sherwood code 16.162.090). The standards apply when exterior remodeling goes through land use approval there. A panel-and-batten wall is made of 4-by-8 sheets, so ask the City whether one qualifies before pricing it; the Sherwood page has the overlay’s full list.
  • Wilsonville’s Villebois. The Village Zone’s table of permitted materials for single-family houses allows board and batten in a set proportion, which “shall not exceed 10″, and 2″ running alternately”, allows plywood with battens only away from the primary facade, and lets materials change only at a horizontal line or an inside corner (Wilsonville code 4.125, Table V-3). In Old Town Wilsonville the residential design standards rule out vinyl, hardboard and oriented strand board siding; the Wilsonville page explains how remodels there are reviewed.
  • Portland’s historic and conservation districts. In a City Historic District, replacing siding needs historic resource review even when the new material matches the old (City of Portland). In a Conservation District, the design standards that let a project skip review accept wood siding only as shingles or horizontal siding, and exclude plywood and composite panels (Chapter 33.218), so a board-and-batten re-side there goes to review as well. The Portland siding permits and districts page explains how to check an address.

Elsewhere, check any homeowners association’s rules before choosing.

What board and batten siding costs

None of the dated sources behind this site’s cost table prices board and batten as a style, so there is no Portland figure for it. The nearest numbers are for the material underneath, per square foot of wall:

  • Fiber cement, installed in Portland: $9 to $16 (Angi, Portland market, checked September 27, 2026).
  • Engineered wood such as LP SmartSide: $7 to $12 (HomeGuide, national).
  • Cedar: $6 to $16 (HomeGuide, national).
  • Vinyl: $3 to $12 per square foot of siding (Fixr, national).

Siding is priced by the area of wall, not the floor area of the house, and none of those sources says whether battens, blocking or furring, floor-line flashing or band boards fall inside its range. Ask each contractor to list those, along with tear-off of the old siding, which HomeGuide’s national guide puts at $70 to $200 per square (100 square feet of wall). Every figure above, with its source, is on the siding cost page.

Start My Siding Quote

No cost and no obligation. Tell us about the house and the siding problem to get started.

Questions, answered

Common questions

How expensive is board and batten siding?

No source this site uses prices board and batten as a style, so the nearest figures are for the material underneath, per square foot of wall: installed fiber cement at $9 to $16 in Angi's Portland guide, and engineered wood at $7 to $12, cedar at $6 to $16 and vinyl at $3 to $12 in national guides. None says whether battens, blocking or floor-line flashing are included, so ask for them as separate lines.

How much does it cost to board and batten a 2,000 sq ft house?

Siding is priced by wall area, not by the floor area of the house, and two 2,000 square foot houses can carry very different amounts of wall. Measure the walls, or ask the contractor for the figure, then price it per square foot: each 1,000 square feet of wall comes to $9,000 to $16,000 at Angi's Portland range for installed fiber cement, or $6,000 to $16,000 at HomeGuide's national range for cedar. Tear-off, sheathing repair and paint are priced on top.

What kind of wood is used for board and batten?

Western red cedar is the wood the Western Red Cedar Lumber Association's guidance covers: rough-sawn unseasoned boards, or boards surfaced on one side and two edges, from 1x2 to 1x12, with 1x3 battens over 1x10 boards a frequent combination. The association recommends nails of hot-dipped galvanized steel, aluminum or stainless steel, calls stainless the best choice, and warns that copper and plain steel react with the wood and stain it.

What are the disadvantages of board and batten siding?

Mostly in the details. Every vertical board puts end grain at its bottom edge, where the USDA Wood Handbook says liquid water enters 10 to 100 times faster than through the other faces, so bottom edges need sealing and clearance. The boards need blocking, furring or solid sheathing to nail into, and panel versions need a flashed joint at the floor line of a two-storey wall. In Portland's historic and conservation districts, and some suburban design zones, the style or the material can need review or be ruled out.

Can I put board and batten siding on a house in a Portland historic district?

Only through review. In a City Historic District, replacing siding needs historic resource review even when the new material matches the old, so a change to board and batten is reviewed. In a Conservation District, the design standards that let work skip review accept wood siding only as shingles or horizontal boards and rule out plywood and composite panels, so a board-and-batten re-side there goes to review as well. Check the address on PortlandMaps first.

A free siding quote request

Start My Siding Quote

No cost and no obligation. Tell us about the house and the siding problem to get started.

No cost to submit a request, and no obligation.